Content-type: text/html
Manpage of ipmiseld.conf
ipmiseld.conf
Section: ipmiseld.conf (5)
Updated: 2024-01-27
Index
Return to Main Contents
NAME
ipmiseld.conf - ipmiseld configuration file
DESCRIPTION
The
ipmiseld
configuration file configures the
ipmiseld
daemon.
The default configuration file loaded is /etc/freeipmi//ipmiseld.conf.
The configuration options that can be specified in the configuration
file are listed below. Each configuration option must be listed on a
separate line. Arguments for an option are separated by any amount of
whitespace. Multiple arguments are also separated by whitespace.
Comments can be marked by using the pound sign ("#") character, and
lines can be continued on the next using backslash ("\").
Note that it is possible to list the username, password and other
potentially sensitive information in the configuration file. If this
data is stored in a configuration file, system administrators should
limit access to this file.
IPMISELD CONFIGURATION OPTIONS
- driver-type IPMIDRIVER
-
Specify the driver type to use.
- disable-auto-probe ENABLE|DISABLE
-
Specify if IPMI devices should be probed for settings.
- driver-address DRIVER-ADDRESS
-
Specify the in-band driver address to use.
- driver-device DEVICE
-
Specify the in-band driver device path to use.
- register-spacing REGISTER-SPACING
-
Specify the in-band driver register spacing to use.
- target-channel-number CHANNEL-NUMBERFR
-
Specify the in-band driver target channel number.
target-slave-address SLAVE-ADDRESSFR-
Specify the in-band driver target slave address.
hostname IPMIHOST1,IPMIHOST2,... -
Specify the remote host(s) to communicate with. Multiple hostnames may
be separated by comma or may be specified in a range format.
- username USERNAME
-
Specify the username to use.
- password PASSWORD
-
Specify the password to use.
- k_g str
-
Specify the BMC key (K_g) to use. Prefix with '0x' to enter
the key in hex.
- session-timeout MILLISECONDS
-
Specify the session timeout length to use in milliseconds.
- retransmission-timeout MILLISECONDS
-
Specify the retransmission timeout length to use in
milliseconds.
- authentication-type AUTHENTICATION-TYPE
-
Specify the authentication type to use. The following
authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2,
and MD5.
- cipher-suite-id CIPHER-SUITE-ID
-
Specify the cipher suite id to use. The following cipher suite
ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- privilege-level PRIVILEGE-LEVEL
-
Specify the privilege type to use. The following privilege
levels are supported: USER, OPERATOR, ADMIN.
- workaround-flags WORKAROUNDS
-
Specify workaround flags to use. Multiple workarounds can be
specified separated by whitespace. Please see tool manpages for
details about available workarounds for each tool. The following
workarounds are supported: assumeio, spinpoll, idzero, forcepermsg,
unexpectedauth, endianseq, authcap, intel20, supermicro20, sun20,
opensesspriv, integritycheckvalue, assumesystemevent.
- verbose-count COUNT
-
Specify default verbose count to use for
ipmi-sel(8).
- sensors-types TYPE-LIST
-
Specify sensor types of SEL events to log. Multiple types can be
specified separated by whitespace. Users may specify sensor types by
string or by number (decimal or hex). Please see
ipmi-sel(8)
--list-types option to see possible string input types.
- exclude-sensor-types ENSOR-TYPES-LIST
-
Specify sensor types of SEL events to not log. default sensor types
to not show sensor outputs for. Multiple sensor types can be
specified separated by whitespace. Users may specify sensor types by
string or by number. Please see
ipmi-sel(8)
--list-types option to see possible string input types.
- system-event-only ENABLE|DISABLE
-
Specify if output should only include system event records.
- oem-event-only ENABLE|DISABLE
-
Specify if output should only include OEM event records.
- event-state-config-file FILE
-
Specify the event state configuration file.
- interpret-oem-data ENABLE|DISABLE
-
Specify if
ipmiseld
should attempt to interpret OEM data or not.
- entity-sensor-names ENABLE|DISABLE
-
Specify if output of sensor names should include entity ids and
instances or not.
- non-abbreviated-units ENABLE|DISABLE
-
Specify if output should have units abbreviated by default or not.
- event-state-filter FILTERSTRING
-
Specify event states to be filtered out and not logged.
- --warning-threshold PERCENTINT
-
Specify SEL fullness warning threshold as an integer percentage.
- --clear-threshold PERCENTINT
-
Specify SEL fullness clear threshold as an integer percentage.
- system-event-format FORMATSTRING
-
Specify the format of the log output when a SEL system event is
encountered.
- oem-timestamped-event-format FORMATSTRING
-
Specify the format of the log output when a SEL OEM timestamped event
is encountered.
- oem-non-timestamped-event-format FORMATSTRING
-
Specify the format of the log output when a SEL OEM non-timestamped
event is encountered.
- poll-interval SECONDS
-
Specify the poll interval to check the SEL for new events.
- log-facility STRING
-
Specify the log facility to use.
- log-priority STRING
-
Specify the log priority to use.
- cache-directory DIRECTORY
-
Specify the cache directory to use.
- ignore-sdr DISABLE
-
Specify if the SDR should be ignored.
- re-download-sdr DISABLE
-
Specify if the SDR should be re-downloaded on start.
- clear-sel DISABLE
-
Specify if the SEL should be cleared on start.
- threadpool-count NUM
-
Specify the threadpool count for parallel SEL polling.
FILES
/etc/freeipmi//ipmiseld.conf
REPORTING BUGS
Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.
COPYRIGHT
Copyright (C) 2012-2015 Lawrence Livermore National Security, LLC.
SEE ALSO
ipmiseld(8), ipmi-sel(8)
http://www.gnu.org/software/freeipmi/
Index
- NAME
-
- DESCRIPTION
-
- IPMISELD CONFIGURATION OPTIONS
-
- FILES
-
- REPORTING BUGS
-
- COPYRIGHT
-
- SEE ALSO
-
This document was created by
man2html,
using the manual pages.
Time: 16:52:47 GMT, January 28, 2024